The SLIN (Smart Lighting Interface Node) module from Liteleds provides all the functions for efficient lighting management. The module enables management of public lighting assets, control of luminaire lifetimes, detection of system faults, real-time monitoring of electrical parameters, dimming for LED luminaires and automation for intelligent management of lighting parks. Encapsulated in the ANSI C.136.41 standard, the device is easily installed in any luminaire with a NEMA 7 socket.
The SLIN (Smart Lighting Interface Node) module from Liteleds features all the functions for efficient lighting management
| Model | LIN 40W | LIN 60W | LIN 80W | LIN 100W | |
|---|---|---|---|---|---|
| Nominal Power | 40 W | 60 W | 80 W | 100 W | |
| Nominal Voltage | 100 to 277 Vac | ||||
| Nominal Frequency | 50/60 Hz | ||||
| Power Factor | > 0,95 | ||||
| Harmonic Distortion - THDi | < 10% | ||||
| Surge Protection | 5 kV (IEC61000-4-5 2014) Class II | ||||
| Total Luminous Flux | 5200 Lm | 7800 Lm | 10400 Lm | 13000 Lm | |
| Luminous Efficacy | 130 Lm/W | ||||
| Color Rendering Index | > 80 | ||||
| Color Temperature | 3000K / 4000K / 5000K / 6500 K | ||||
| Lens Angle | 60 / 90º / 110º | ||||
| LED Lifespan | 100,000 h | ||||
| Luminaire Lifespan | 50,000 h | ||||
| IP Protection Rating | IP 42 | ||||
| Operating Temperature | -5ºC to +50ºC | ||||
| Protection Against Electric Shock | Class I | ||||
| Mechanical Resistance | IK 08 | ||||
| Net Weight | 1,2 Kg | 1,2 Kg | 2,1 Kg | 2,1 Kg | |
| Luminaire Material | Extruded aluminum | ||||
| Lens Material | PMMA | ||||
| Fixation | Fixed rod | ||||
| Validity | Undetermined | ||||
| Warranty | 5 years | ||||
| Dimensions (A x B x C) | 580 x 50 x 120 mm | 580 x 50 x 120 mm | 860 x 50 x 120 mm | 860 x 50 x 120 mm | |
| Dimming | 0-10V (Optional) | ||||
NBR IEC 60598-1 – luminaires – Part 1: general requirements and tests;
NBR IEC 62262 – Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code);
IEC/PAS 62722-2-1 – Luminaire Performance – Part 2-1: Particular requirements for LED luminaires;
IEC 61000-4-4 – Electromagnetic Compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test;
IEC 61000-4-5 – Electromagnetic Compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test;
NBR 16026 – DC or AC electronic control gear for LED modules – Performance requirements;
ABNT NBR IEC 60529:2005 – Degrees of protection for enclosures of electrical equipment (IP Code);
IES LM-79 – Electrical and Photometric Measurements of Solid-State Lighting Products;
IES LM-80 – Measuring lumen maintenance of led light sources.